pspm_convert_ecg2hb_amri

Back to index

Description

pspm_convert_ecg2hb_amri performs R-peak detection from an ECG signal using the steps decribed in R-peak detection section of [1]. This function uses a modified version of the original amri_eeg_rpeak.m code that can be obtained from [2]. The modified version with a list of changes made is provided with PsPM in the amri_eegfmri directory.

Format

[sts, channel_index] = pspm_convert_ecg2hb_amri(fn) or [sts, channel_index] = pspm_convert_ecg2hb_amri(fn, options)

Arguments

Variable Definition
fn [string] Path to the PsPM file which contains the pupil data.
options See following fields.
options.channel [optional, numeric/string, default: ‘ecg’, i.e. last ECG channel in the file] Channel type or channel ID to be preprocessed. Channel can be specified by its index (numeric) in the file, or by channel type (string). If there are multiple channels with this type, only the last one will be processed. If you want to detect R-peaks for several ECG channels in a PsPM file, call this function multiple times with the index of each channel. In this case, set the option ‘channel_action’ to ‘add’, to store each resulting ‘hb’ channel separately.
options.signal_to_use [‘ecg’/’teo’/’auto’, default as ‘auto’] Choose which signal will be used as the input to the core R-peak detection steps. (1) If ‘ecg’, filtered ECG signal will be used. (2) If ‘teo’, Teager Enery Operator will be applied to the filtered ECG signal before feeding it to R-peak finding part. (3) If ‘auto’, the option that results in the higher maximal auto-correlation will be used.
options.hrrange [numeric 2-element vector, unit: beats per minute] Minimum and maximum heartbeat rates (BPM) to use in the algorithm. Default is 20-200 bpm.
options.ecg_bandpass [numeric, unit: Hz] Minimum and maximum frequencies to use during bandpass filter of the raw ECG signal to construct filtered ECG signal. Default is 0.5-40 Hz.
options.teo_bandpass [numeric 2-element vector, unit: Hz] Minimum and maximum frequencies to use during bandpass filter of filtered ECG signal to construct TEO input signal. Default is 8-40 Hz.
options.teo_order [numeric, default as 1] Order of the TEO operator. Must be integer. For a discrete time signal x(t) and order k, TEO[x(t); k] is defined as TEO[x(t); k] = x(t)x(t) - x(t-k)x(t+k).
options.min_cross_corr [numeric, default as 0.5] Minimum cross correlation between a candidate R-peak and the found template such that the candidate is classified as an R-peak.
options.min_relative_amplitude [numeric, default as 0.4] Minimum relative peak amplitude of a candidate R-peak such that it is classified as an R-peak.
options.channel_action [‘add’/’replace’] Defines whether corrected data should be added or the corresponding preprocessed channel should be replaced. Note that ‘replace’ mode does not replace the raw data channel, but a previously stored heartbeat channel. Default as ‘replace’.

Outputs

Variable Definition
sts status marker showing whether the function works normally.
channel_index index of channel containing the processed data.

References

[1] Liu, Zhongming, et al. “Statistical feature extraction for artifact removal from concurrent fMRI-EEG recordings.” Neuroimage 59.3 (2012): 2073-2087.